Lightning Protection Software — LPS Manager
« From risk assessment to inspection reporting — LPS Manager covers the full lifecycle of your lightning protection system, in compliance with IEC 62305. »
LPS Manager is the professional lightning protection software built for installers, inspectors, and multi-site facility managers worldwide. Designed around international standards — primarily IEC 62305-1/2/3/4 — it centralises every aspect of your lightning risk management in a single, cloud-based platform. Whether you manage one site or thousands, LPS Manager gives you the tools to work faster, stay compliant with IEC 62305, and share results instantly.
4 Core Functions of LPS Manager
LPS Manager covers the full lifecycle of a Lightning Protection System (LPS) — from initial risk assessment to ongoing maintenance tracking — in strict compliance with IEC 62305.
- Risk assessment & NPF calculation — Automated computation of lightning strike frequency (Nd) vs. tolerable risk (NT) per IEC 62305-2. Generates the required Lightning Protection Level (LPL I–IV) for each installation.
- LPS design & compliance check — Generates Lightning Protection Zones (LPZ), validates air-termination placement using the rolling sphere method, mesh method, and protection angle method per IEC 62305-3. Checks down-conductor routing and earth termination system adequacy.
- Inspection & maintenance tracking — Logs periodic inspections, records earth resistance measurements, tracks component lifecycle (lightning rods, SPDs, equipotential bonding conductors), and manages non-conformity corrective actions.
- Audit reporting & documentation — Produces client-ready reports with full risk analysis (Nd / NT), installation drawings, LPZ diagrams, compliance status per IEC 62305, and inspection history.
A Complete Software for Lightning Protection Management
LPS Manager brings together all critical workflows of a lightning protection software under one roof. Engineers and field technicians no longer need to juggle multiple tools or paper files.
- Risk assessment & NPF calculation based on IEC 62305-2 — automated Nd vs. NT computation, LPL determination
- LPS design validation — LPZ mapping, rolling sphere method, air-termination and down-conductor checks per IEC 62305-3
- Inspection and audit reporting — periodic checks, earth resistance records, SPD lifecycle tracking, compliance summaries, shareable PDFs
- Real-time lightning monitoring and alerts — no hardware installation required
- Multi-site collaboration — shared files, professional directory, BMS/SCADA API integration
- Multi-brand compatibility — works with all lightning rod and SPD brands
The platform is available in four languages (French, English, Spanish, Portuguese) and runs natively on iOS, Android, Windows 11, macOS, and any modern web browser.
Risk Assessment & NPF Calculation Based on IEC 62305-2
Accurate risk assessment is at the heart of any reliable lightning protection software. LPS Manager implements the risk assessment methodology defined in IEC 62305-2 to determine the required Lightning Protection Level (LPL) and verify that the annual frequency of dangerous events (Nd) does not exceed the tolerable risk (NT).
- Nd (annual number of dangerous events) is computed automatically from structure dimensions, Ng/Nsg ground flash density, and environmental correction factors
- NT (tolerable frequency) is derived from the acceptable risk threshold for the type of structure and its contents
- LPL I to IV (Lightning Protection Level) is assigned based on the Nd / NT ratio, driving the selection of protection measures
- NPF (Niveau de Protection Foudre) — equivalent French designation — is computed on-site via guided forms, automatically sourcing Nsg data from Strike Radar
- All input parameters — building dimensions, use, contents, shielding, location — are captured through structured guided forms
- Results are stored in the installation file and embedded in compliance reports
Note: LPS Manager handles NPF/LPL-level risk assessment per IEC 62305-2. For extended ARF (Annual Risk of Failure) calculations, LPS Designer Pro is the dedicated tool.
LPS Design & Compliance Validation (IEC 62305-3)
Beyond risk assessment, LPS Manager assists engineers in designing and validating the physical components of the Lightning Protection System (LPS) — covering both the protection against direct and indirect effects of lightning, in line with IEC 62305-3.
- Lightning Protection Zones (LPZ) — automated LPZ 0A, 0B, 1, 2+ zoning based on the structure and the required LPL
- Rolling sphere method — validates air-termination placement (Franklin rods, catenary wires, mesh conductors) for the selected LPL radius
- Down-conductor routing — checks number, spacing, and material compliance per IEC 62305-3 requirements
- Earth termination system — records electrode type (ring, foundation, radial), dimensions, and measured resistance values
- Equipotential bonding — documents bonding connections between the LPS, electrical installations, and metallic structures
- SPD (Surge Protective Device) selection — logs SPD type, installation point, and coordination with the LPZ boundaries
Installation File Management
Every site managed in LPS Manager has a structured installation file that captures the complete history of its lightning protection system. Field technicians and office managers always share the same up-to-date reference.
- Detailed description of the structure, materials, and dimensions
- Equipment inventory: lightning rods, down conductors, earth termination system electrodes, SPDs
- Photo documentation attached directly to each component
- Technical drawings and plans uploaded and version-tracked
- Equipotential bonding records and bonding conductor inventory
- Full audit trail of every modification
LPS Manager is compatible with all lightning rod and surge arrester brands, including products available at lpsfr.com — lightning rods and lpsfr.com — accessories & earthing.
Inspections, Audits and Compliance
IEC 62305-3 requires periodic verification of lightning protection installations. LPS Manager includes a dedicated inspection and audit module that guides users through every check step and generates compliant reports automatically.
- Structured inspection checklists aligned with IEC 62305-3 requirements
- On-site data entry — works offline, syncs when connected
- Earth resistance measurement logging per visit, with historical trend view
- SPD and equipotential bonding component status tracking
- Instant shareable PDF reports for clients, insurers, or regulatory bodies
- Inspection history linked to each installation file
- Non-conformity tracking with corrective action follow-up
Your entire compliance record is always accessible, searchable, and audit-ready — eliminating the risk of lost paperwork or outdated files.
Real-Time Weather Monitoring and Lightning Alerts
One of the most distinctive features of this lightning protection software is its built-in real-time lightning monitoring — available free of charge to all users, with no sensor installation required.
- Live lightning strike data aggregated from international detection networks
- Automatic alerts when lightning activity approaches a monitored site
- Configurable alert radius and notification preferences
- Historical lightning data for post-event analysis
- Available worldwide — no geographic restriction
This capability is particularly valuable for multi-site managers who need to monitor exposure to both direct and indirect effects of lightning across geographically dispersed facilities simultaneously, without investing in dedicated hardware at each location.
Multi-Site Management and Collaboration
LPS Manager is engineered for professionals who manage lightning protection across multiple sites. It supports team-based workflows and large-scale portfolio management out of the box.
- Centralised dashboard for all sites, with LPL status indicators and alerts
- Shared file access for field teams and office staff
- Professional directory to manage client and contractor contacts
- Open API for integration with BMS (Building Management Systems) and SCADA platforms
- Role-based access control — define permissions per user and per site
The cloud-based architecture ensures that all data is always synchronised across devices, so teams in the field and in the office always work from the same information.
Who Uses LPS Manager?
This lightning protection software is used by a wide range of professionals and organisations across the globe. It is specifically designed to meet the requirements of technically demanding users who work with IEC 62305.
- Lightning protection installers — manage LPS installations, generate inspection reports, and collaborate with clients
- Independent inspectors and auditors — conduct compliant audits and issue verified reports per IEC 62305-3
- Multi-site facility managers — oversee portfolios of protected assets with real-time monitoring and LPZ status
- Engineering and consulting firms — integrate risk assessment (Nd / NT) into broader electrical safety projects
- Institutions and public bodies — hospitals, airports, energy utilities, data centres, heritage buildings
- Insurance professionals — verify compliance status and document risk mitigation measures
International Standards Compliance
LPS Manager is built around the IEC 62305 international standard series, which defines requirements for the protection of structures and persons against direct and indirect effects of lightning.
- IEC 62305-1 — General principles: defines terms (LPS, LPL, LPZ, SPD, down-conductor, earth termination system, equipotential bonding) and fundamental protection concepts
- IEC 62305-2 — Risk management: Nd / NT computation, LPL determination, risk components — fully integrated into the calculation module
- IEC 62305-3 — Physical damage to structures: rolling sphere method, LPZ design, down-conductor and earth termination system requirements — supported in the design validation module
- IEC 62305-4 — Electrical and electronic systems: SPD coordination, equipotential bonding at LPZ boundaries — tracked in the installation file
- BS EN 62305 — UK national adoption of IEC 62305 — fully compatible with LPS Manager workflows
- NF C 17-102 — Supported for Early Streamer Emission (ESE) lightning rods alongside conventional LPS components
- FD C 17-108 — Simplified risk assessment method (NPF calculation) integrated into the calculation module for French installations
LPS Manager is suitable for professionals operating in any regulatory context — whether projects follow IEC 62305, BS EN 62305, NF C 17-102, or a combination of these standards.
Available on All Platforms
A truly effective lightning protection software must be accessible wherever professionals work — in the office, on site, or on the move. LPS Manager is available natively on every major platform.
- iOS — iPhone and iPad, available on the App Store
- Android — smartphones and tablets, available on Google Play
- Windows 11 — desktop application for office workflows
- macOS — native Mac application
- Web browser — no installation required, access from any device
All data is synchronised in real time across devices via the cloud, so switching between your phone on site and your desktop in the office is completely seamless.
Pricing — Free to Expert Plans
LPS Manager offers a range of plans to suit individual professionals and large organisations alike. The free plan already includes full lightning monitoring capabilities — no credit card required.
- Free — Real-time lightning monitoring, basic site management, unlimited alerts
- Data — 2.99 €/month — Access to historical lightning data and extended statistics
- Pro — 9.99 €/month — Full installation file management, inspection reports, NPF/LPL calculations per IEC 62305-2
- Expert — 29.99 €/month — Multi-site portfolio management, LPZ design tools, API access, priority support
- Enterprise — Custom pricing for large organisations with advanced integration and SLA requirements
Ready to modernise your lightning protection management?
Download LPS Manager today and start managing your LPS installations, inspections, and real-time monitoring — all in one place, on any device, in compliance with IEC 62305.